American Journal of Respiratory and Critical Care Medicine · 2017 · 70 citations · 39 references
MedicineInternal MedicineHemodynamic ManagementPulmonary Function TestingSleep MedicineContinuous Positive Airway PressureEndothelial DysfunctionMandibular Advancement TherapyPositive Airway Pressure TherapySleep Apnea CareSleep HealthApnea-hypopnea Index ReductionCardiovascular Late EffectsEndothelial Dysfunction AssessmentMandibular Advancement SurgeryObstructive Sleep Apnea TherapyObstructive Sleep Apnea TreatmentSleep Apnea Outcome MeasurementVascular Endothelial Dysfunction
RATIONALE: Endothelial dysfunction, a major predictor of late cardiovascular events, is linked to the severity of obstructive sleep apnea (OSA). OBJECTIVES: To determine whether treatment with mandibular advancement device, the main alternative to continuous positive airway pressure, improves endothelial function in patients with severe OSA. METHODS: In this trial, we randomized patients with severe OSA and no overt cardiovascular disease to receive 2 months of treatment with either effective mandibular advancement device or a sham device. The primary outcome, change in reactive hyperemia index, a validated measurement of endothelial function, was assessed on an intention-to-treat basis. An embedded microsensor objectively measured treatment compliance. MEASUREMENTS AND MAIN RESULTS: A total of 150 patients (86% males; mean [SD] age, 54 [10] yr; median [interquartile range] apnea-hypopnea index, 41 [35-53]; mean [SD] Epworth sleepiness scale, 9.3 [4.2]) were randomized to effective mandibular advancement device (n = 75) or sham device (n = 75). On intention-to-treat analysis, effective mandibular advancement device therapy was not associated with improvement of endothelial function compared with the sham device. Office and ambulatory blood pressure outcomes did not differ between the two groups. Effective mandibular advancement device therapy was associated with significant improvements in apnea-hypopnea index (P < 0.001); microarousal index (P = 0.008); and symptoms of snoring, fatigue, and sleepiness (P < 0.001). Mean (SD) objective compliance was 6.6 (1.4) h/night with the effective mandibular advancement device versus 5.6 (2.3) h/night with the sham device (P = 0.006). CONCLUSIONS: In moderately sleepy patients with severe OSA, mandibular advancement therapy reduced OSA severity and related symptoms but had no effect on endothelial function and blood pressure despite high treatment compliance. Clinical trial registered with www.clinicaltrials.gov (NCT 01426607).
39
Richard B. Berry, Rohit Budhiraja, Daniel J. Gottlieb et al. · Journal of Clinical Sleep Medicine · 2012 · 5.2K citations · Full text
Increased Prevalence of Sleep-Disordered Breathing in Adults
P. E. Peppard, Terry Young, Jodi H. Barnet et al. · American Journal of Epidemiology · 2013 · 4.6K citations · Full text
Medicine, Population Health Sciences, Behavioral Epidemiology +10
CPAP for Prevention of Cardiovascular Events in Obstructive Sleep Apnea
R. Doug McEvoy, Nick A. Antic, Emma Heeley et al. · New England Journal of Medicine · 2016 · 2K citations