Consideration of environmental and functional factors in calibration of antenna integrated active phased array transmitters

Kaan Temir, Murat Sencer Akyüz, Yaşar Kemal

2016 · 15 citations · 3 references

Concepts

Abstract

When dealing with direct calibration in phased array systems, in which power amplifier (PA) output for each antenna element is measured with respect to all phase and amplitude levels, several issues complicate the calibration algorithm and extend calibration time, such as wide frequency band, large element number, temperature changes, driving power of PAs. In this work, all realizable aspects effecting direct calibration of multi-octave band phased array system with 100+ elements are examined and a robust and consistent algorithm is developed and applied.

References

3