An image-guided precision proton radiation platform for preclinical<i>in vivo</i>research

Elizabeth Ford, Robert Emery, Daniel T Huff, M.V. Narayanan, J Schwartz, Ning Cao, Juergen Meyer, Ramesh Rengan, Jing Zeng, George A. Sandison,

Physics in Medicine and Biology · 2016 · 44 citations · 62 references

Concepts

Abstract

(10% peak dose). Alignment of the proton beam with the SARRP system isocenter was measured at 0.24 mm agreement. The width of the beam changes very little with depth. Monte Carlo-based calculations of dose using the CT image data set as input demonstrate in vivo use. Monte Carlo simulations of the modulated 100 MeV clinical proton beam show a significantly reduced Bragg peak. We demonstrate the feasibility of a proton beam integrated with a commercial x-ray image-guidance system for preclinical in vivo studies. To our knowledge this is the first description of an experimental image-guided proton beam for preclinical radiobiology research. It will enable in vivo investigations of radiobiological effects in proton beams.

References

62