Neutronics optimization and characterization of a long-life SCO<sub>2</sub>-cooled micro modular reactor

Yonghee Kim, Donny Hartanto, Hwanyeal Yu

International Journal of Energy Research · 2016 · 26 citations · 9 references

Concepts

TL;DR

The micro modular reactor is a fast‑spectrum, truck‑transportable design delivering 36.2 MWth with a 20‑year, refueling‑free lifetime. This study optimizes neutronics of a supercritical CO₂‑cooled MMR and adopts hexagonal fuel assemblies to maximize fuel inventory. Using Serpent Monte‑Carlo neutronics and depletion calculations, the authors compare U15N and UC fuels, minimize excess reactivity below one dollar with a replaceable fixed absorber, reduce primary control drums, and characterize safety parameters such as control‑rod worth, reactivity coefficients, and power peaking factors as a function of burnup. © 2016 John Wiley & Sons, Ltd.

Abstract

This paper presents a neutronics optimization study of a supercritical CO2-cooled micro modular reactor (MMR). The MMR is a fast-spectrum reactor designed to be an extremely compact, integrated, and truck-transportable reactor with 36.2-MWth power and a 20-year lifetime without refueling. The reactor uses a drum-type primary control system and a single absorber rod located at the core center as the secondary ultimate shutdown system. In order to maximize the fuel inventory in a compact fast reactor, hexagonal fuel assemblies are adopted in this work. We compare two types of MMR: One is using U15N fuel, and the other one is based on UC fuel. In addition, the minimization of the core excess reactivity to less than 1 dollar is also achieved in this study by a unique application of a replaceable fixed absorber in order to enhance safety of the MMR core by preventing the possibility of a prompt criticality accident. Moreover, the required number of primary control drums is also reduced through minimization of the excess reactivity. Several important safety parameters such as control rod/drum worth, reactivity coefficients, and power peaking factors are also characterized as a function of core burnup. The neutronics analyses and depletion calculations are all performed using the continuous-energy Monte Carlo Serpent code with the latest evaluated nuclear data file (ENDF/B-VII.1) library. Copyright © 2016 John Wiley & Sons, Ltd.

References

9