THE ACCELEROMETER MMG MEASUREMENT APPROACH, IN MONITORING THE MUSCULAR FATIGUE

M. T. Tarata, A. Spaepen, Robert Puers

2001 · 23 citations · 3 references

Concepts

Abstract

This research aimed to appreciate whether the mechanomyogram (MMG) may be used to monitor the muscle behavior under fatiguing exercise. The electromyogram (EMG) and MMG were simultaneously recorded from the Biceps and from the Brachioradialis muscles, with surface electrodes - EMG, and accelerometer based transducers - MMG, from sixteen subjects. The conclusions are consistent in validating the use of the median frequency (MF) MMG to monitor the development of the muscular fatigue in the isometric isotonic exercise, at 25 % maximal voluntary contraction (MVC). The same as for the MF EMG, the MF MMG steadily decreases from the very beginning of the exercise, down to exhaustion, again demonstrating the central component of the muscular fatigue. The sustained muscular contractions externally associated with not being able to maintain a certain force, lead to physiological fatigue, tremor or pain, localized in the specific muscle. This is the so called localized muscular fatigue (Basmajian, 1985), associated with a compression of the power spectral density (PSD) of the EMG towards lower frequencies (Stulen et al., 1981, Tarata, 1994), measured by MF computed from the EMG PSD. This is due to the reduction in the conduction velocity in direct relation with the membrane excitability and with neural adaptations, resulting in an increase of the lower frequency content of the signal. It has been shown that, in sustained motor tasks, changes at different levels, including motoneural discharge, develop before an endurance limit is reached, the phenomenon called central fatigue (Gandevia, 1998). When considering an isometric contraction, mechanical vibrations occur, due to three main processes: the inner muscular vibrations, which are the intrinsic components of the muscle contraction (Barry, 1992), oscillations of the human motor system, e.g. tremor and clonus (Iaizzo et al., 1992), and artefacts. They are located in specific frequency ranges, with a certain overlapping: the artefacts - due to large movements- the lowest frequencies, tremor - in humans has been located under 10Hz independent of subject, between 5.85 and 8.8 Hz (Comby, 1992), and the mechanical inner vibrations between 10 and 40 Hz. It has been shown that the EMG and MMG recorded simultaneously from the same muscle have similar behavior (Tarata, 1997, Tarata et al., 1997, 1999). This research aimes to appreciate whether the MMG may be used to monitor the muscle behavior under fatiguing exercise. 2. METHOD

References

3