EngineeringChemical EngineeringEnvironmental EngineeringEnvironmental RemediationWastewater TreatmentWater TreatmentHerbicide SciencePesticide RemediationWastewater BiotreatmentWastewater CharacterizationChemical Oxygen DemandDependent VariablesHerbicide RemediationIndependent VariablesOxidation ProcessesPesticide Removal EfficiencyRunoff Water TreatmentTaguchi Designs
This research was to study the efficiency of the Fenton's treatment process for the removal of three herbicides, namely 2,4-dichlorophenoxy acetic acid (2,4-D), ametryn and dicamba from the sugarcane field runoff water. The treatment process was designed with the Taguchi approach by varying the four factors such as H2O2/COD (1–3.5), H2O2/Fe2+ (5–50), pH (2–5) and reaction time (30–240 min) as independent variables. Influence of these parameters on chemical oxygen demand (COD), ametryn, dicamba and 2,4-D removal efficiencies (dependent variables) were investigated by performing signal to noise ratio and other statistical analysis. The optimum conditions were found to be H2O2/COD: 2.125, H2O2/Fe2+: 27.5, pH: 3.5 and reaction time of 135 min for removal efficiencies of 100% for ametryn, 95.42% for dicamba, 88.2% for 2,4-D and with 75% of overall COD removal efficiencies. However, the percentage contribution of H2O2/COD ratio was observed to be significant among all four independent variables and were 44.16%, 67.57%, 51.85% and 50.66% for %COD, ametryn, dicamba and 2,4-D removal efficiencies, respectively. The maximum removal of herbicides was observed with the H2O2 dosage of 5.44 mM and Fe2+ dosage of 0.12 mM at pH 3.5.