2012 · 11 citations · 1 references
EngineeringMechanical EngineeringEnergy SystemsHeat TransferThermal AnalysisAir Temperature EffectsGas Turbine EnginesAmbient Temperature EffectsCombined Cycle Power PlantsHeat Rate AnalysisHeat Transfer RateMass Flow RatePower OutputSteam Turbine OperationTurbine Operation
The performance of the power plant strongly depends on ambient air temperature (AAT).Mass flow rate (kg/s) of air decreases in summer with increasing AAT for the same volumetric flow rate (m 3 /s), which results in reduced power output of turbine and increased heat rate. This paper analyzes the effects of the AAT on various parameters of power plant viz., mass flow rate of air, fuel consumption, steam, power output of turbine, efficiency and heat rate of gas turbine, steam turbine and combined cycle plant. The results of analysis performed are discussed for 10MW power plant. The effect of increases in ambient air temperature by 30c, the net power output found to be decreased by 18% with 11% decrease mass flow rate of inlet air.
1
W. E. Stewart · ASHRAE journal · 1998 · 10 citations
Engineering, Aerospace Engineering, Mechanical Engineering +10