Therapeutic Drug Monitoring · 2016 · 79 citations · 38 references
PharmacyPharmaceutical AnalysisPharmacologyChromatographic AnalysisClinical PharmacologyMass Spectrometric AnalysisAnalytical ChromatographyBioanalytical Method ValidationChromatographyInstrumental AnalysisLiquid ChromatographyTyrosine Kinase InhibitorsDrug Combination TherapyHigh-performance Liquid Chromatography-mass SpectrometryLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisTandem Mass SpectrometryTandem Mass Spectrometry AnalysisUltra-performance Liquid Chromatography Method DevelopmentUltra-performance Liquid Chromatography-mass Spectrometry
BACKGROUND: A sensitive liquid chromatography coupled with tandem mass spectrometry (MS/MS) method for the analysis in a small volume of plasma of 14 tyrosine kinase inhibitors currently used (imatinib, dasatinib, ibrutinib, ponatinib, trametinib, sunitinib, cobimetinib, dabrafenib, erlotinib, lapatinib, nilotinib, bosutinib, sorafenib, and vemurafenib) has been developed and validated. This multianalyte liquid chromatography coupled with MS/MS assay is of interest for anticancer drug combination therapy. METHODS: After a simple protein precipitation of plasma samples, the chromatographic separation was performed using an ultra performance liquid chromatography system coupled with MS/MS in a positive ionization mode. The mobile phase consisted of a gradient elution of 10 mmol/L formate ammonium buffer containing 0.1% (vol/vol) formic acid (phase A) and acetonitrile with 0.1% (vol/vol) formic acid (phase B) at a flow rate of 300 μL/min. RESULTS: The analysis time was 5.0 minutes per run, and all analytes and internal standard eluted within 1.45-1.79 minutes. The calibration curves were linear over the range from 1 to 500 ng/mL for bosutinib, cobimetinib, dasatinib, ibrutinib, and trametinib, from 5 to 500 ng/mL for ponatinib and sunitinib; from 50 to 2500 ng/mL for lapatinib; from 750 to 100,000 ng/mL for vemurafenib, and from 10 to 2500 ng/mL for dabrafenib, erlotinib, imatinib, nilotinib, and sorafenib, with coefficients of correlation above 0.99 for all analytes. The intra- and interday imprecisions were below 14.36%. CONCLUSIONS: This method was successfully applied to therapeutic drug monitoring in clinical practice.
38
Sorafenib in Advanced Clear-Cell Renal-Cell Carcinoma
Bernard Escudier, Tim Eisen, Walter M. Stadler et al. · New England Journal of Medicine · 2007 · 4.8K citations · Full text
Medicine, Nephrology, Oncology +11
Scott M. Wilhelm, Christopher Carter, LiYa Tang et al. · Cancer Research · 2004 · 4K citations · Full text
Medicine, Oncology, Pharmacology +17
Erlotinib in Lung Cancer — Molecular and Clinical Predictors of Outcome
Ming‐Sound Tsao, Akira Sakurada, Jean-Claude Cutz et al. · New England Journal of Medicine · 2005 · 1.9K citations
Medicine, Oncology, Pharmacology +14