EngineeringElectrical EngineeringEnergy SystemsPower ElectronicsRenewable Energy SystemsActive FiltersPower Grid AnalysisPower QualityPower SystemsThree-phase CircuitsVoltage RegulationActive Harmonic FilteringActive Power FilterCurrentsHarmonic ReductionHarmonicsPower FactorPower Factor ControlReactive Power Compensation
In this paper, an active power line conditioner is conceived for harmonic and reactive power compensation in the single-phase to three-phase systems. The proposed system is divided into two classes: a) parallel active power filter at the single-phase grid side; and b) series active power filter at the three-phase load side. Compared with conventional five-leg single-phase to three-phase converter, the proposed system presents some advantages, like lower dc-link voltages and lower currents of the legs. A suitable control strategy is presented to regulate the load voltages, power factor of the grid close to one, and to minimize the voltage and current harmonics simultaneously. Simulated and experimental results are also presented.
15
Trends in active power line conditioners
Hirofumi Akagi · IEEE Transactions on Power Electronics · 1994 · 616 citations · Full text