Transient thermal analysis using both lumped-circuit approach and finite element method of a permanent magnet traction motor

Y.K. Chin, D.A. Staton

2005 · 46 citations · 8 references

Concepts

Abstract

This work presents the transient thermal analysis of a permanent magnet (PM) synchronous traction motor. The motor has magnets inset into the surface of the rotor to give a maximum field-weakening range of between 2 and 2.5. Both analytically based lumped circuit and numerical finite element methods have been used to simulate the motor. A comparison of the two methods is made showing the advantages and disadvantages of each. Simulation results are compared with practical measurements.

References

8