ClinicoEconomics and Outcomes Research · 2016 · 11 citations · 29 references
PharmacyCardiologyPharmacoeconomicsCost-effectiveness AnalysisHealth EconomicsHealth Technology AssessmentBattery TechnologyCost-effectiveness ComparisonCost-effectiveness ModelingHealth Care CostsHealthcare Cost AnalysisMedical Device EvaluationBase Case ModelingCost Savings AnalysisCost Savings EvaluationDirect Cost AnalysisHealth Care EconomicsHealth Care PerspectiveHealth System PerspectiveImplantable Cardioverter Defibrillators
OBJECTIVE: The objective of this study was to quantify the impact that longer battery life of cardiac resynchronization therapy defibrillator (CRT-D) devices has on reducing the number of device replacements and associated costs of these replacements from a Swedish health care system perspective. METHODS: An economic model based on real-world published data was developed to estimate cost savings and avoided device replacements for CRT-Ds with longer battery life compared with devices with industry-standard battery life expectancy. Base-case comparisons were performed among CRT-Ds of three manufacturers - Boston Scientific Corporation, St. Jude Medical, and Medtronic - over a 6-year time horizon, as per the available clinical data. As a sensitivity analysis, we evaluated CRT-Ds as well as single-chamber implantable cardioverter defibrillator (ICD-VR) and dual-chamber implantable cardioverter defibrillator (ICD-DR) devices over a longer 10-year period. All costs were in 2015 Swedish Krona (SEK) discounted at 3% per annum. RESULTS: Base-case analysis results show that up to 603 replacements and up to SEK 60.4 million cumulative-associated costs could be avoided over 6 years by using devices with extended battery life. The pattern of savings over time suggests that savings are modest initially but increase rapidly beginning in the third year of follow-up with each year's cumulative savings two to three times the previous year. Evaluating CRT-D, ICD-VR, and ICD-DR devices together over a longer 10-year period, the sensitivity analysis showed 2,820 fewer replacement procedures and associated cost savings of SEK 249.3 million for all defibrillators with extended battery life. CONCLUSION: Extended battery life is likely to reduce device replacements and associated complications and costs, which may result in important cost savings and a more efficient use of health care resources as well as a better quality of life for heart failure patients in Sweden.
29
Cecilia Linde, William T. Abraham, Michael R. Gold et al. · Journal of the American College of Cardiology · 2008 · 1.3K citations · Full text
Michele Brignole, Angelo Auricchio, Gonzalo Barón‐Esquivias et al. · EP Europace · 2013 · 1.1K citations · Full text