This work reports on the characterization of the Multi-Pixel Photon Counter (MPPC) detectors as a function of the temperature and bias voltage. Devices of 1×1 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and 3×3 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> total area and 50×50 μm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> μcell size produced by Hamamatsu Photonics have been studied. The temperature has been varied from -110°C to -50°C using a cryostat cooled by liquid nitrogen and from 0 to 38°C using a climatic chamber. Important electrical parameters of the MPPC detectors as gain, breakdown voltage, quenching resistance, capacitance and dark count rate have been measured.