22-gauge core <i>vs</i> 22-gauge aspiration needle for endoscopic ultrasound-guided sampling of abdominal masses

William Sterlacci, Athanasios D. Sioulas, Lothar Veits, Pervin Gönüllü, Guido Schachschal, Stefan Groth, Mario Anders, Christos K. Kontos, T Topalidis, Andrea Hinsch,

World Journal of Gastroenterology · 2016 · 40 citations · 39 references

DOIFull text

Open access

Concepts

Abstract

AIM: To compare the aspiration needle (AN) and core biopsy needle (PC) in endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of abdominal masses. METHODS: Consecutive patients referred for EUS-FNA were included in this prospective single-center trial. Each patient underwent a puncture of the lesion with both standard 22-gauge (G) AN (Echo Tip Ultra; Cook Medical, Bloomington, Indiana, United States) and the novel 22G PC (EchoTip ProCore; Cook Medical, Bloomington, Indiana, United States) in a randomized fashion; histology was attempted in the PC group only. The main study endpoint was the overall diagnostic accuracy, including the contribution of histology to the final diagnosis. Secondary outcome measures included material adequacy, number of needle passes, and complications. RESULTS: = 0.034); no other differences were of statistical significance. CONCLUSION: Both needles achieved high overall diagnostic yields and similar performance characteristics for cytological diagnosis; histological analysis was only possible in 2/3 of cases with the new needle.

References