Acta Ophthalmologica · 2016 · 40 citations · 39 references
Natural SciencesOphthalmologyVision ScienceBiomedical OpticsClinical Vision ScienceOcular ImagingFluorescence ImagingFluorescence SpectroscopyMacular DiseaseMacular ImagingOphthalmic ImagingOptical Coherence TomographyAutofluorescenceFluorescence LifetimeFluorescence Lifetime ImagingFluorescence Lifetime MeasurementsFundus Autofluorescence ImagingMacular Pigment ChangesMacular Pigment DensityMacular Pigment Effects
Abstract Purpose To investigate the impact of macular pigment ( MP ) on fundus autofluorescence ( FAF ) lifetimes in vivo by characterizing full‐thickness idiopathic macular holes ( MH ) and macular pseudo‐holes ( MPH ). Methods A total of 37 patients with MH and 52 with MPH were included. Using the fluorescence lifetime imaging ophthalmoscope ( FLIO ), based on a Heidelberg Engineering Spectralis system, a 30° retinal field was investigated. FAF decays were detected in a short (498–560 nm; ch1) and long (560–720 nm; ch2) wavelength channel. τ m , the mean fluorescence lifetime, was calculated from a three‐exponential approximation of the FAF decays. Macular coherence tomography scans were recorded, and macular pigment's optical density ( MPOD ) was measured (one‐wavelength reflectometry). Two MH subgroups were analysed according to the presence or absence of an operculum above the MH . A total of 17 healthy fellow eyes were included. A longitudinal FAF decay examination was conducted in nine patients, which were followed up after surgery and showed a closed MH . Results In MH without opercula, significant τ m differences (p < 0.001) were found between the hole area ( MH a) and surrounding areas ( MH b) (ch1: MH a 238 ± 64 ps, MH b 181 ± 78 ps; ch2: MH a 275 ± 49 ps, MH b 223 ± 48 ps), as well as between MH a and healthy eyes or closed MH . Shorter τ m , adjacent to the hole, can be assigned to areas with equivalently higher MPOD . Opercula containing MP also show short τ m . In MPH , the intactness of the Hele fibre layer is associated with shortest τ m . Conclusions Shortest τ m originates from MP ‐containing retinal layers, especially from the Henle fibre layer. Fluorescence lifetime imaging ophthalmoscope (FLIO) provides information on the MP distribution, the pathogenesis and topology of MH . Macular pigment (MP) fluorescence may provide a biomarker for monitoring pathological changes in retinal diseases.
39
Vitreous Surgery for Idiopathic Macular Holes
N. Kelly · Archives of Ophthalmology · 1991 · 1.3K citations
Medicine, Ophthalmology, Surgery +13
Idiopathic Senile Macular Hole
J. Donald M. Gass · Archives of Ophthalmology · 1988 · 989 citations
Medicine, Ophthalmology, Surgery +12
Distribution of Cones in Human and Monkey Retina: Individual Variability and Radial Asymmetry
Christine A. Curcio, Kenneth R. Sloan, Orin Packer et al. · Science · 1987 · 596 citations
Prevalence and Associations of Epiretinal Membranes
Wayne Smith, Tien Chey, Jie Jin Wang et al. · Ophthalmology · 1997 · 503 citations