Journal of Cerebral Blood Flow & Metabolism · 2016 · 54 citations · 29 references
MedicineNeurologyNeuroscienceBiomedical ImagingDiagnostic ImagingMagnetic Resonance BiophysicsCerebral Blood FlowCerebral EdemaDiffusion ImagingMagnetic Resonance ImagingStrokeStroke ImagingArterial Spin LabelingBlood-brain Barrier PermeabilityBlood-brain Barrier Permeability ImagingBrain PermeabilityDiffusion Magnetic Resonance ImagingIschemia-induced Barrier DisruptionIschemic Stroke Diffusion ImagingStroke-associated Barrier Dysfunction
Diffusion-weighted arterial spin labeling magnetic resonance imaging has recently been proposed to quantify the rate of water exchange (K w ) across the blood–brain barrier in humans. This study aimed to evaluate the blood–brain barrier disruption in transient (60 min) ischemic stroke using K w magnetic resonance imaging with cross-validation by dynamic contrast-enhanced magnetic resonance imaging and Evans blue histology in the same rats. The major findings were: (i) at 90 min after stroke (30 min after reperfusion), group K w magnetic resonance imaging data showed no significant blood–brain barrier permeability changes, although a few animals showed slightly abnormal K w . Dynamic contrast-enhanced magnetic resonance imaging confirmed this finding in the same animals. (ii) At two days after stroke, K w magnetic resonance imaging revealed significant blood–brain barrier disruption. Regions with abnormal K w showed substantial overlap with regions of hyperintense T 2 (vasogenic edema) and hyperperfusion. Dynamic contrast-enhanced magnetic resonance imaging and Evans blue histology confirmed these findings in the same animals. The K w values in the normal contralesional hemisphere and the ipsilesional ischemic core two days after stroke were: 363 ± 17 and 261 ± 18 min −1 , respectively (P < 0.05, n = 9). K w magnetic resonance imaging is sensitive to blood–brain barrier permeability changes in stroke, consistent with dynamic contrast-enhanced magnetic resonance imaging and Evans blue extravasation. K w magnetic resonance imaging offers advantages over existing techniques because contrast agent is not needed and repeated measurements can be made for longitudinal monitoring or averaging.
29
Heart Disease and Stroke Statistics—2016 Update
Dariush Mozaffarian, Emelia J. Benjamin, Alan S. Go et al. · Circulation · 2015 · 6.6K citations
James R. Ewing, Robert A. Knight, Tavarekere N. Nagaraja et al. · Magnetic Resonance in Medicine · 2003 · 182 citations · Full text
Medicine, Biophysics, Neuroscience +16