Archives of Pathology & Laboratory Medicine · 2016 · 44 citations · 27 references
PharmacyImmunologyA/b TestingClinical ImmunologyGood Laboratory PracticeAntibody CharacterizationBioanalytical Method ValidationAdditivesAntibody Titer AnalysisAntibody TiteringAntibody TitrationImmunoassay MethodologyProficiency TestingStandard Method Of MeasurementVariability Reduction
CONTEXT: -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. OBJECTIVE: -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. DESIGN: -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. RESULTS: -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. CONCLUSION: -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.
27
Anand Padmanabhan, Laura Connelly‐Smith, Nicole A. Aqui et al. · Journal of Clinical Apheresis · 2019 · 2.2K citations
Pharmacy, Immunology, Aphasia +7
Joseph E. Schwartz, Jeffrey L. Winters, Anand Padmanabhan et al. · Journal of Clinical Apheresis · 2013 · 598 citations
The gel test: a new way to detect red cell antigen‐antibody reactions
Yves Lapierre, D. Rigal, J. Adam et al. · Transfusion · 1990 · 431 citations
Medicine, Hematology, Immunology +16
Cathrine Ebbing, Svein Rasmussen, Torvid Kiserud · Ultrasound in Obstetrics and Gynecology · 2007 · 285 citations · Full text
Factors affecting the antigen-antibody reaction.
Roberto Reverberi, L Reverberi · PubMed · 2007 · 262 citations · Full text
Pharmacy, Chemistry, Immunology +12