Journal of Orthopaedic Research® · 2016 · 470 citations · 58 references
MedicineMaterials EngineeringOrthopedic SurgeryAdditive ManufacturingBiomaterialsOrthopaedic BiomaterialsBone Tissue EngineeringImplant BiomechanicsImplant DesignImplant MaterialsImplant Prosthesis DesignImplantable Biomaterials3D-printed ImplantsBone Material PropertiesFemoral Stem DesignHip Implant BiomechanicsImplant FabricationImplant Material MechanicsOrthopaedic ImplantsOrthopedic Implant Design
Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with tunable mechanical properties is introduced for use in hip replacement design. The implant macro geometry is based off of a short stem taper-wedge implant compatible with minimally invasive hip replacement surgery. The implant micro-architecture is fine-tuned to locally mimic bone tissue properties which results in minimum bone resorption secondary to stress shielding. We present a systematic approach for the design of a 3D printed fully porous hip implant that encompasses the whole activity spectrum of implant development, from concept generation, multiscale mechanics of porous materials, material architecture tailoring, to additive manufacturing, and performance assessment via in vitro experiments in composite femurs. We show that the fully porous implant with an optimized material micro-structure can reduce the amount of bone loss secondary to stress shielding by 75% compared to a fully solid implant. This result also agrees with those of the in vitro quasi-physiological experimental model and the corresponding finite element model for both the optimized fully porous and fully solid implant. These studies demonstrate the merit and the potential of tuning material architecture to achieve a substantial reduction of bone resorption secondary to stress shielding. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1774-1783, 2017.
58
Adaptive bone-remodeling theory applied to prosthetic-design analysis
R. Huiskes, Harrie Weinans, H.J. Grootenboer et al. · Journal of Biomechanics · 1987 · 1.2K citations · Full text
Richard C. Johnston, Robert H. Fitzgerald, William H. Harris et al. · Journal of Bone and Joint Surgery · 1990 · 810 citations · Full text
Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)
Jayanthi Parthasarathy, Binil Starly, Shivakumar Raman et al. · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · 2009 · 808 citations
Natural Sciences, Materials Engineering, Materials Science +10