Publication | Open Access
Experimental Efficiency Comparison Between a Direct Matrix Converter and an Indirect Matrix Converter Using Both Si IGBTs and SiC <sc>mosfet</sc>s
51
Citations
24
References
2016
Year
Electrical EngineeringEngineeringPower DevicePower Semiconductor DevicePower Electronics ConverterDirect Matrix ConverterElectric Power ConversionPower InverterPower ElectronicsMicroelectronicsIndirect Matrix ConverterGate Bipolar Transistor
This paper presents an experimental efficiency comparison study between two different direct ac-ac converter topologies; a direct matrix converter and an indirect matrix converter. The evaluation is performed under variable load conditions using both discrete silicon isolated gate bipolar transistor and silicon carbide MOSFETs working at power levels up to 9 kW. Each loss measurement is carried out using two power analyzers; one placed at the input and one at the output of the converter under study. To facilitate this measurement, an output filter was necessary in addition to the normal input filter. Both converters are modulated using the same traditional symmetrical space vector approach and feature an identical input/output filter design.
| Year | Citations | |
|---|---|---|
Page 1
Page 1