Tetsu-to-Hagane · 1983 · 12 citations · 0 references
EngineeringMaterials ScienceMechanical EngineeringHeat TransferMetallurgyTransport PhenomenaBoiling Heat TransferHeat ConductionHeat Transfer AnalysisHeat Transfer FundamentalsHeat Transfer In FluidsHeat Transfer ModelingBoiling Heat Transfer CoefficientHeat Transfer CoefficientsHeat Transfer MechanismsRadiation Heat TransferSpray CoolingSurface Heat Transfer CoefficientsSurface TemperatureWater Vapor Flux
Heat transfer coefficients (α) of water-spray cooling in the region of steel surface temperature (θs) 400 to 800°C are numerically expressed as a function of θs and impinged water flux (W), by using published water-spray cooling data (7 papers, 112 data) measured with scale-coated steel specimens by many researchers. In the region of θs : 400 to 800°C and W: 10 to 2 000 l/m2 · min, αw is represented by the following equation, αw=2.292 × 108 · W0.616θs 2.445where αw is value of α without radiation heat transfer, [αw] being kcal/m2· h ·°C.In addition, are discussed features of exponents of W and θs, comparison of the above equation with other researchers' one, α in the film boiling region, and α calculation methods for θs between 125°Cand about 1 200°C.