Heat Transfer Coefficients in the Surface Temperature Range of 400 to 800°C during Water-spray Cooling of Hot Steel Product

Masashi Mitsutsuka

Tetsu-to-Hagane · 1983 · 12 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

Heat transfer coefficients (α) of water-spray cooling in the region of steel surface temperature (θs) 400 to 800°C are numerically expressed as a function of θs and impinged water flux (W), by using published water-spray cooling data (7 papers, 112 data) measured with scale-coated steel specimens by many researchers. In the region of θs : 400 to 800°C and W: 10 to 2 000 l/m2 · min, αw is represented by the following equation, αw=2.292 × 108 · W0.616θs 2.445where αw is value of α without radiation heat transfer, [αw] being kcal/m2· h ·°C.In addition, are discussed features of exponents of W and θs, comparison of the above equation with other researchers' one, α in the film boiling region, and α calculation methods for θs between 125°Cand about 1 200°C.