Noninvasive and continuous real-time monitoring, easy handling, minimal size, high tolerability, and affordable costs make pulse oximetry, which has become widely used in human anesthesia, attractive to avian anesthesia as well. It is the only noninvasive method of estimating the arterial oxygen status. Arterial oxygen saturation and pulse rate are measured photometrically by photoelectric detection of the hemoglobin derivates in a pulsating arterial vessel. In our study, spectralphotometric analyses revealed a different photometric behavior of avian and human he- moglobin, which is expected to result in an underestimation of the actual saturation value in birds. Further, the application was tested clinically in pigeons and parrots. We used two commercially available pulse oximeters, one of which was modified for the first time to allow measurements in birds with high pulse rates. The trend of oxygenation was well recorded, but the saturation values recorded by pulse oximetry did not correlate well (r = .81) with arterial saturation derived from blood gas analyses and calculation. Pulse rate and heart rate correlated very well in both pulse oximeters tested. Although the monitoring by pulse oximetry is accurate and continuous in a calmly lying patient, motion artifacts occurred with the beginning of surgery. Critical incidents, like dys- rhythmia or severe blood loss, were marked by fluctuation and discontinuity of the displayed values, which, however, failed to record the actual values. The pulse oximeter was reduced to its alarm function. We conclude that pulse oximetry is not satisfactory for routine use in avian practice because of motion artifact and limited feasibility in critical incidents. To adapt the method to avian patients, an avian calibration curve-which would consider the specific avian photometric behavior of hemoglobin as well as photometric effects of the tissue-and a more useful artifact suppression or an ECG-triggered instrument may be required.
11
Clinical Avian Medicine and Surgery
Richard B. Davis, Greg J. Harrison, Linda R. Harrison · Avian Diseases · 1987 · 381 citations
Peter Lutz, I. S. Longmuir, Knut Schmidt‐Nielsen · Respiration Physiology · 1974 · 74 citations