International Journal of Geomechanics · 2016 · 26 citations · 20 references
EngineeringCivil EngineeringFoundation EngineeringGeotechnical EngineeringSoil MechanicsBearing CapacityFoundation ConstructionFoundation SystemsShallow FoundationsBearing Capacity AssessmentBearing Capacity Of Eccentric LoadingBearing Capacity ReductionEccentric Loading EffectsExperimental Testing Of Shallow FoundationsLoad EccentricityShallow Foundation Bearing CapacityUltimate Bearing Capacity
An empirical nondimensional reduction factor is proposed in this paper, which can be used for determining the ultimate bearing capacity of eccentrically and/or obliquely loaded shallow strip foundations embedded in sand. This was developed after analyzing a series of laboratory model test results available in the literature on strip foundations. The depth of foundation (D), eccentricity of load (e), and inclination of load (α)varied from 0 to 1B, 0 to 0.5B, and 0 to 20°, respectively, where B refers to the width of foundation. The proposed reduction factor was found to provide reasonably well results for calculating the ultimate bearing capacity of shallow strip foundation under eccentric and/or inclined loads. The results obtained by using the proposed method have been found to be in good agreement with widely used traditional methods available in the literature.
20