Journal of Ophthalmic and Vision Research · 2016 · 14 citations · 35 references
MedicineOphthalmologySurgeryOcular DiseaseOphthalmic SurgeryRefractive SurgeryContact Lens Clinical PracticeContact Lens FittingContact Lens InterventionsKeratoconus Lens FittingPreoperative Refractive EvaluationScleral LensesContact Lens EfficacyCorneal Higher-order AberrationsCorneal Inlay ImplantationKeratoconus FittingMini-scleral Lens FittingMini-scleral LensesOcular Comfort AssessmentUncorrected Visual Acuity
PURPOSE: To evaluate the feasibility and efficacy of mini-scleral design (MSD) contact lenses to treat keratoconus patients who were unsatisfied with the results of corneal inlay. METHODS: In this prospective interventional case series, 9 eyes of 6 keratoconus patients who were unsatisfied with the results of corneal inlay were fitted with MSD contact lenses. Demographic data, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and higher order aberrations (HOAs) were evaluated before contact lens fitting. Corrected visual acuity by placing the MSD contact lens with or without over-refraction, and HOAs were measured one hour after contact lens fitting. One month after contact lens wearing, corrected visual acuity by placing the MSD contact lens with over-refraction and possible contact lens related problems were assessed. Ocular comfort and contact lens handling problems were asked in follow-up visits. The data was analyzed using descriptive statistical tests. RESULTS: Nine eyes of 6 patients were successfully fitted with the mini-scleral lens. Fitting was ideal in 7 eyes and acceptable in 2 eyes. Mean corrected visual acuity by placing the MSD lens without over-refraction was 0.09 (range, 0.00-0.15) LogMAR which was significantly better than the mean BSCVA of 0.38 (range, 0.2-0.6) LogMAR (P = 0.007). The mean root mean square (RMS) of third-order coma and trefoil significantly decreased after MSD contact lens fitting (P = 0.012 and P = 0.015, respectively); however, changes in the fourth-order spherical aberration were not statistically significant (P = 0.336). CONCLUSION: Mini-scleral contact lenses may be helpful in the management of visually unsatisfied patients after corneal inlay.
35
Correcting keratoconus with intracorneal rings
Joseph Colin, Béatrice Cochener, Gwenaelle Savary et al. · Journal of Cataract & Refractive Surgery · 2000 · 542 citations
Medicine, Ophthalmology, Surgery +16
INTACS inserts for treating keratoconus
Joseph Colin, Béatrice Cochener, Gwenaelle Savary et al. · Ophthalmology · 2001 · 265 citations
Wavefront aberrations measured with Hartmann-Shack sensor in patients with keratoconus
Naoyuki Maeda, Takashi Fujikado, Teruhito Kuroda et al. · Ophthalmology · 2002 · 244 citations
Brian S. Boxer Wachler, Naveen S Chandra, Brian Chou et al. · Ophthalmology · 2003 · 208 citations
Management of keratoconus with Intacs
Charalambos S. Siganos, George D. Kymionis, Nikos Kartakis et al. · American Journal of Ophthalmology · 2002 · 177 citations
Medicine, Dermatology, Ophthalmology +10