Sour Service Limits of 13% Cr and Super 13% Cr Stainless Steels for OCTG: Effect of Environmental Factors

Hervé Marchebois, Hafida El Alami, Jean Leyer, Arnaud Gateaud

2009 · 20 citations · 5 references

Concepts

Abstract

Abstract For the last 25 years, the use of 13% Cr seamless steel tubing has been a cost effective solution for preventing sweet CO2 corrosion. More recently, Super 13% Cr alloys with low carbon and Ni-Mo additions were introduced for improving the resistance to specific forms of corrosion. This paper summarizes the SSC results of both conventional 13% Cr and super 13% Cr stainless steels. NACE Uniaxial Tensile tests were performed according to the Fitness-For-Purpose approach recommended in the new edition of NACE MR0175/ISO 15156. The role of chloride content was investigated when combined with PH2S and pH in environments where SSC is likely to occur. These mappings enable the definition of usage domains for Super 13% Cr stainless steel in sour service.

References

5