Applied Physics Research · 2016 · 11 citations · 7 references
EngineeringMaterials EngineeringMaterials ScienceRadiation PhysicsRadiation ProtectionRadiation ShieldingLead ShieldingRadiation-resistant MaterialsShielding DesignShielding MaterialsX-ray ShieldingAttenuation MeasurementBackscatter RadiationLead-based Shielding MaterialsRadiation BackscatterShielding Against X-raysShielding Material ComparisonShielding PrinciplesX-ray Attenuation Coefficients
This paper reports the comparative study of X-ray attenuation using different materials which can be utilized to design anti-backscattered grids and radiation protection shields. The characteristics of X-ray attenuation in several materials, namely, lead, copper, iron steel, and aluminum, are investigated under diverse exposure parameters to measure their ability to attenuate incident X-ray and their capability to reduce backscattered X-ray. Lead and iron steel shields exhibit the best abilities in attenuating X-ray, whereas aluminum shield shows the least attenuation ability. This study proposes a design of a unique method for assessing the backscatter X-ray dose. The iron steel grid based on iron steel plate provides the best value in reducing backscattered radiation (up to 34.78%) compared with other conventional plate materials.
7
Diagnostic reference levels in intraoral dental radiography in Korea
Eun‐Kyung Kim, Won-Jeong Han, Jin-Woo Choi et al. · Imaging Science in Dentistry · 2012 · 28 citations · Full text
Dentistry, Oral Radiology, Radiology +13