Rapid Communications in Mass Spectrometry · 2016 · 13 citations · 19 references
Natural SciencesEarth SciencesSoil SciencesElemental AnalysisGeochemistryMass Spectrometric AnalysisIsotope GeochemistryMass Spectrometric Elemental AnalysisMass SpectrometryOrganic Elemental AnalysisStable Isotope AnalysisStable Isotope GeochemistryCarbon Isotopes In SoilIsotope Ratio AnalysisIsotope Ratio Mass SpectrometryIsotopic Ratio DeterminationNitrogen Isotope AnalysisStable Carbon IsotopesStable Isotope RatiosSulfur Isotope Analysis
RATIONALE: Information about the sulfur stable isotope composition (δ(34) S value) of organic materials and sediments, in addition to their nitrogen (δ(15) N value) and carbon (δ(13) C value) stable isotope compositions, can provide insights into mechanisms and processes in different areas of biological and geological research. The quantification of δ(34) S values has traditionally required an additional and often more difficult analytical procedure than NC dual analysis. Here, we report on the development of a high-throughput method that simultaneously measures the elemental and isotopic compositions of N, C and S in a single sample, and over a wide range of sample sizes and C/N and C/S ratios. METHODS: We tested a commercially available CHNOS elemental analyzer in line with an isotope ratio mass spectrometer for the simultaneous quantification of N, C and S stable isotope ratios and contents, and modified the elemental analyzer in order to overcome the interference of (18) O in δ(34) S values, to minimize any water condensation that could also influence S memory, and to achieve the complete reduction of nitrogen oxides to N2 gas for accurate measurement of δ(15) N values. A selection of organic materials and soils was analyzed with a ratio of 1:1.4 standards to unknowns per run. RESULTS: The modifications allowed high quality measurements for N, C and S isotope ratios simultaneously (1 SD of ±0.13‰ for δ(15) N value, ±0.12‰ for δ(13) C value, and ±0.4‰ for δ(34) S value), with high throughput (>75 unknowns per run) and over a wide range of element amount per capsule (25 to 500 μg N, 200-4000 μg C, and 8-120 μg S). CONCLUSIONS: This method is suitable for widespread use and can significantly enhance the application of δ(34) S measurements in a broad range of soils and organic samples in ecological and biogeochemical research. Copyright © 2016 John Wiley & Sons, Ltd.
19
STABLE ISOTOPES IN ECOSYSTEM STUDIES
Bruce J. Peterson, Brian Fry · Annual Review of Ecology and Systematics · 1987 · 5.4K citations
Variation in trophic shift for stable isotope ratios of carbon, nitrogen, and sulfur
James H. McCutchan, William M. Lewis, Carol Kendall et al. · Oikos · 2003 · 2.7K citations
Principles of stable isotope geochemistry
Choice Reviews Online · 2007 · 922 citations
Biogeochemistry of Sulfur Isotopes
Donald E. Canfield · Reviews in Mineralogy and Geochemistry · 2001 · 705 citations