EuroIntervention · 2016 · 234 citations · 26 references
MedicineCardiologySurgeryCardiothoracic SurgeryDiagnostic ImagingInterventional CardiologyAortic StenosisBrain ImagingMagnetic Resonance ImagingPostoperative Neurologic AssessmentStrokeBaseline Neurocognitive TestingCerebral Protection During Aortic SurgeryDiffusion Magnetic Resonance ImagingNeurocognitive DeficitsNeurocognitive FunctioningNeurocognitive ImpairmentNeurocognitive ProfilePostoperative Diffusion-weighted Imaging
AIMS: Our aim was to determine whether use of the filter-based Sentinel™ Cerebral Protection System (CPS) during transcatheter aortic valve implantation (TAVI) can affect the early incidence of new brain lesions, as assessed by diffusion-weighted magnetic resonance imaging (DW-MRI), and neurocognitive performance. METHODS AND RESULTS: From January 2013 to July 2015, 65 patients were randomised 1:1 to transfemoral TAVI with or without the Sentinel CPS. Patients underwent DW-MRI and extensive neurological examination, including neurocognitive testing one day before and five to seven days after TAVI. Follow-up DW-MRI and neurocognitive testing was completed in 57% and 80%, respectively. New brain lesions were found in 78% of patients with follow-up MRI. Patients with the Sentinel CPS had numerically fewer new lesions and a smaller total lesion volume (95 mm3 [IQR 10-257] vs. 197 mm3 [95-525]). Overall, 27% of Sentinel CPS patients and 13% of control patients had no new lesions. Ten or more new brain lesions were found only in the control cohort (in 20% vs. 0% in the Sentinel CPS cohort, p=0.03). Neurocognitive deterioration was present in 4% of patients with Sentinel CPS vs. 27% of patients without (p=0.017). The filters captured debris in all patients with Sentinel CPS protection. CONCLUSIONS: Filter-based embolic protection captures debris en route to the brain in all patients undergoing TAVI. This study suggests that its use can lead to fewer and overall smaller new brain lesions, as assessed by MRI, and preservation of neurocognitive performance early after TAVI. CLINICAL TRIAL REGISTRATION: Dutch trial register-ID: NTR4236. URL http://www.trialregister.nl/trialreg/admin/rctsearch.asp?Term=mistral.
26
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Craig R. Smith, Martin B. Leon, Michael J. Mack et al. · New England Journal of Medicine · 2011 · 6.3K citations · Full text
Medicine, Cardiology, Surgery +13
Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis
Alain Cribier, Hélène Eltchaninoff, Assaf Bash et al. · Circulation · 2002 · 3.2K citations · Full text
Medicine, Cardiology, Surgery +16
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
David Adams, Jeffrey J. Popma, Michael J. Reardon et al. · New England Journal of Medicine · 2014 · 2.9K citations · Full text
Medicine, Cardiology, Surgery +13
Silent Brain Infarcts and the Risk of Dementia and Cognitive Decline
Sarah E. Vermeer, Niels D. Prins, Tom den Heijer et al. · New England Journal of Medicine · 2003 · 2.3K citations · Full text