Journal of Hospital Infection · 2016 · 26 citations · 11 references
Life SciencesBiomedical EngineeringMicrobiologyElectrochemical EngineeringInfection PreventionMedical MicrobiologyBiofilm FormationCleaning OperationsEnvironmental CleaningEnvironmental DisinfectionSterile ProcessingWater SanitationAutomated CleaningAutomated Cleaning SystemsBiofilm RemovalCleaningCleaning DisinfectionHospital Surface ContaminationMicrobial Contamination Control
BACKGROUND: Washbasin U-bends are reservoirs of microbial contamination in healthcare environments. U-Bends are constantly full of water and harbour microbial biofilm. AIM: To develop an effective automated cleaning and disinfection system for U-bends using two solutions generated by electrochemical activation of brine including the disinfectant anolyte (predominantly hypochlorous acid) and catholyte (predominantly sodium hydroxide) with detergent properties. METHODS: Initially three washbasin U-bends were manually filled with catholyte followed by anolyte for 5min each once weekly for five weeks. A programmable system was then developed with one washbasin that automated this process. This U-bend had three cycles of 5min catholyte followed by 5min anolyte treatment per week for three months. Quantitative bacterial counts from treated and control U-bends were determined on blood agar (CBA), R2A, PAS, and PA agars following automated treatment and on CBA and R2A following manual treatment. FINDINGS: The average bacterial density from untreated U-bends throughout the study was >1×10(5) cfu/swab on all media with Pseudomonas aeruginosa accounting for ∼50% of counts. Manual U-bend electrochemically activated (ECA) solution treatment reduced counts significantly (<100cfu/swab) (P<0.01 for CBA; P<0.005 for R2A). Similarly, counts from the automated ECA-treatment U-bend were significantly reduced with average counts for 35 cycles on CBA, R2A, PAS, and PA of 2.1±4.5 (P<0.0001), 13.1±30.1 (P<0.05), 0.7±2.8 (P<0.001), and 0 (P<0.05) cfu/swab, respectively. P. aeruginosa was eliminated from all treated U-bends. CONCLUSION: Automated ECA treatment of washbasin U-bends consistently minimizes microbial contamination.
11
Susy Hota, Zahir Hirji, Karen Stockton et al. · Infection Control and Hospital Epidemiology · 2008 · 363 citations
Damien Roux, Benjamin Aubier, Hélène Cochard et al. · Journal of Hospital Infection · 2013 · 103 citations
Carlo La Forgia, John E. Franke, Donna M. Hacek et al. · American Journal of Infection Control · 2009 · 89 citations