Concepedia

Publication | Closed Access

Current sensor fault detection and isolation method for PMSM drives, using average normalised currents

55

Citations

4

References

2016

Year

Abstract

A new approach for current sensor fault detection and isolation (FDI) for permanent magnet synchronous motor (PMSM) drives is presented. Contrary to the classical approaches for sensors fault diagnosis, based on residual generation through observers or parity equations, the proposed technique uses the average normalised machine‐phase currents. The main advantages of this approach are that it does not need any information about the PMSM or inverter models, and it involves low tuning efforts, that make it suitable for real‐time implementation with good reliability. The good performance and the robustness of the proposed FDI approach are illustrated through experimental results.

References

YearCitations