Evaluation of J-R curve testing of nuclear piping materials using the direct current potential drop technique

EM Hackett, M. Kirk, Richard A. Hays

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1986 · 11 citations · 0 references

Concepts

Abstract

A method is described for developing J-R curves for nuclear piping materials using the DC Potential Drop (DCPD) technique. Experimental calibration curves were developed for both three point bend and compact specimen geometries using ASTM A106 steel, a type 304 stainless steel and a high strength aluminum alloy. These curves were fit with a power law expression over the range of crack extension encountered during J-R curve tests (0.6 a/W to 0.8 a/W). The calibration curves were insensitive to both material and sidegrooving and depended solely on specimen geometry and lead attachment points. Crack initiation in J-R curve tests using DCPD was determined by a deviation from a linear region on a plot of COD vs. DCPD. The validity of this criterion for ASTM A106 steel was determined by a series of multispecimen tests that bracketed the initiation region. A statistical differential slope procedure for determination of the crack initiation point is presented and discussed. J-R curve tests were performed on ASTM A106 steel and type 304 stainless steel using both the elastic compliance and DCPD techniques to assess R-curve comparability. J-R curves determined using the two approaches were found to be in good agreement for ASTM A106 steel. Themore » applicability of the DCPD technique to type 304 stainless steel and high rate loading of ferromagnetic materials is discussed. 15 refs., 33 figs.« less