Imaging Science in Dentistry · 2016 · 40 citations · 23 references
DentistryMaxillofacial RadiologyOral RadiologyDental RadiologyDiagnostic ImagingMaxillofacial ImagingComputed TomographyCone Beam Computed Tomography InterpretationDental AnatomyDental ImagingMaxillofacial RadiographyThree-dimensional ReconstructionAccuracyCaliper MeasurementGround-truth ValidationInter-observer AgreementIntraclass CorrelationMaxillary MeasurementsVoxels-based MeasurementWilcoxon Signed-rank Test
PURPOSE: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. MATERIALS AND METHODS: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view (13 cm×16 cm) and small field of view (5 cm×8 cm) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. RESULTS: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. CONCLUSION: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.
23
Accuracy in measurement of distance using limited cone-beam computerized tomography.
Kaoru Kobayashi, Shinji Shimoda, Yoichi Nakagawa et al. · PubMed · 2004 · 410 citations
Dentistry, Oral Radiology, Radiology +17
Cynthia Leung, Leena Palomo, Richard Griffith et al. · American Journal of Orthodontics and Dentofacial Orthopedics · 2010 · 351 citations · Full text
Dentistry, Oral Radiology, Radiology +14
Accuracy of three-dimensional measurements using cone-beam CT
HM Pinsky, S Dyda, RW Pinsky et al. · Dentomaxillofacial Radiology · 2006 · 344 citations