International Journal of Heat and Technology · 2016 · 23 citations · 17 references
EngineeringMechanical EngineeringHeat TransferThermal AnalysisThermodynamicsHeat ExchangersHeat FlowHeat Transfer AnalysisHeat Transfer In FluidsSolar Thermal SystemsThermal DesignHeat Exchanger PerformanceHeat Transfer EnhancementHeat Transfer In DuctsPitch-to-diameter RatioReynolds NumberSwirlThermal Fluid DynamicsThermal Performance Of Ducts
Experimental investigations on heat transfer enhancement by swirl generators are presented. The thermo hydraulic performance has been evaluated. The experiments were conducted over a wide range of Reynolds number from 993 to 12,034 by employing air (Pr = 0.7) as the working fluid. The major findings of this experimental investigation are that the circular grooved tube with different diameter ratio (h = d/D = 0.04 and 0.06) and pitch ratio (y = p/D = 1.5 and 3.0) perform better than the smooth duct. In evaluation of thermal performance, it is seen that the bluff cylinder of (y = 1.5, h =0.06) are thermodynamically advantageous than the other roughness used. The result is useful for heat exchanger, solar air-heater, etc.
17
Sh. Ghadirijafarbeigloo, Mahmood Yaghoubi · Energy Procedia · 2014 · 171 citations · Full text
Engineering, Mechanical Engineering, Computational Heat Transfer +16