Journal of Nuclear Medicine · 2016 · 133 citations · 33 references
MedicineCardiologyNuclear MedicineCardiac Nuclear MedicineDiagnostic ImagingDiagnostic Nuclear MedicineCardiac AssessmentCardiac ImagingCardiac Nuclear ImagingCardiovascular ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingAbsolute Myocardial Blood FlowAbsolute Myocardial Flow MeasurementBlood FlowMyocardial Flow ReserveMyocardial Perfusion ReserveMyocardial Uptake QuantificationNitrogen-13 Ammonia ImagingNitrogen-13 Ammonia Perfusion Imaging
Recent advances in SPECT technology including cadmium–zinc–telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare <i>K</i><sub>1</sub> uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET. <b>Methods:</b> Absolute MBF was assessed in 28 consecutive patients undergoing adenosine stress–rest myocardial perfusion imaging (MPI) by <sup>99m</sup>Tc-tetrofosmin CZT SPECT and <sup>13</sup>N-ammonia PET, and MFR was calculated as a ratio of hyperemic over resting MBF. Results from both MPI methods were compared, and correlation coefficients were calculated. The diagnostic accuracy of CZT MFRi to predict an abnormal MFR defined as PET MFR less than 2 was assessed using a receiver-operator-characteristic curve. <b>Results:</b> Median MBF at rest was comparable between CZT and PET (0.89 [interquartile range (IQR), 0.77–1.00] vs. 0.92 [IQR, 0.78–1.06] mL/g/min; <i>P</i> = not significant) whereas it was significantly lower at stress in CZT than PET (1.11 [IQR, 1.00–1.26] vs. 2.06 [IQR, 1.48–2.56] mL/g/min; <i>P</i> < 0.001). This resulted in median MFRi values of 1.32 (IQR, 1.13–1.52) by CZT and 2.36 (IQR, 1.57–2.71) by PET (<i>P</i> < 0.001). The receiver-operator-characteristic curve revealed a cutoff for CZT MFRi at 1.26 to predict an abnormal PET MFR yielding an accuracy of 75%. <b>Conclusion:</b> The estimation of absolute MBF index values by CZT SPECT MPI with <sup>99m</sup>Tc-tetrofosmin is technically feasible, although hyperemic values are significantly lower than from PET with <sup>13</sup>N-ammonia, resulting in a substantial underestimation of MFR. Nevertheless, CZT MFRi may confer diagnostic value.
33
2014 ESC/EACTS Guidelines on myocardial revascularization
European Heart Journal · 2014 · 4.3K citations · Full text
Medicine, Cardiology, Surgery +14
2014 ESC/EACTS Guidelines on myocardial revascularization
Philippe Kolh, Stephan Windecker, Fernándo Alfonso et al. · European Journal of Cardio-Thoracic Surgery · 2014 · 4.2K citations · Full text
Medicine, Cardiology, Surgery +14