Journal of the American Veterinary Medical Association · 1992 · 25 citations · 0 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyElectrophysiologyCardiac ArrhythmiasCardiac PacingPacemaker CareCardiac PacemakersEndocardial PacingIntracardiac PacingPacemaker ComplicationsPacemaker MalfunctionPacemaker PhysiologyPacemaker ProgrammingPermanent Pacemaker Therapy
Pacemakers were successfully implanted in 4 adult and geriatric cats with bradycardia and associated signs. Various implantation techniques were used. Complications developed in 3 of the cats, generally more severe in 2 of the 3 cats in which thoracotomy and celiotomy were performed than in the cat in which a transvenous endocardial pacing technique was used. After surgery, pacemaker functions were reprogrammed noninvasively in 2 cats. All 4 cats survived without syncope for a mean of 33.1 months after surgery.