Comparison of real-time instruments and gravimetric method when measuring particulate matter in a residential building

100

Citations

40

References

2016

Year

Abstract

This study used several real-time and filter-based aerosol instruments to measure PM<sub>2.5</sub> levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real-time monitors is convenient for measurement of airborne PM at short time scales, the accuracy of those monitors depends on a particular instrument. Bias correction factors identified in this paper could provide guidance for other studies using direct-reading instruments to measure PM concentrations.