Pediatric Anesthesia · 2016 · 13 citations · 15 references
NursingToxicologyAnesthetic TechniquesOccupational HealthWorkplace Hazard AssessmentDelivery SystemsExposure MonitoringOccupational Exposure ControlEvacuationInhalation Delivery SystemsNitrous OxideNitrous Oxide ConcentrationNitrous Oxide Delivery SystemsProcedural Pain ControlSafe Exposure LimitsTime-weighted Average Exposure
BACKGROUND: Nitrous oxide (N2 O 50% in oxygen) is commonly used for painful procedures in children. Potential negative health effects associated with chronic workplace exposure limit its use. Safe occupational N2 O exposure concentrations are below 25 ppm environmental concentration as a time-weighted average (TWA) and below 200 ppm as a short-time exposure level (STEL) of 15 min. AIM: The aim was to assess occupational exposure of staff during nitrous oxide administration to children using different inhalation delivery devices and scavenging systems. METHODS: Staff nitrous oxide exposure during use of a double face mask (DFM) with or without a demand valve (DV) was compared with a conventional single face mask (FM). We also compared exposure using the hospital central scavenging system with a portable evacuation system. N2 O concentrations, representing exposure values, were monitored within proximity to staff. Urine N2 O concentration was measured in staff administering the N2 O at the end of the procedural session. RESULTS: The mean and median values of TWA and STEL within the working area were lower than recommended values in the DFM (10.8, 11.6 ppm for TWA; 13.9, 11.0 ppm for STEL) and DFM-DV groups (2.3, 2.8 ppm for TWA; 4.4, 3.5 ppm for STEL) using the portable evacuation system. The N2 O urine exposure in DFM-DV group was lower than DFM group: a mean difference of 9.56 ppm (95% CI 2.65-16.46). Staff N2 O urinary concentrations were within safe biological limits in both the DFM and DFM-DV groups. High exposure concentrations to N2 O were recorded in all FM and FM-DV environmental and biological samples. CONCLUSIONS: The DFM system, with or without a DV, connected to a portable evacuation system during N2 O administration to children for painful procedures kept N2 O levels within the local environment below recommended limits.
15
Nitrous Oxide and Spontaneous Abortion in Female Dental Assistants
Andrew S. Rowland, Donna D. Baird, David Shore et al. · American Journal of Epidemiology · 1995 · 279 citations
Mortality among doctors in different occupations.
Richard Doll, Richard Peto · BMJ · 1977 · 94 citations · Full text
Exposure to Nitrous Oxide and Neurologic Disease among Dental Professionals
Jay B. Brodsky, Ellis N. Cohen, Byron W. Brown et al. · Survey of Anesthesiology · 1982 · 86 citations
Pharmacy, Neurology, Anesthesia +10
Robert F. Harrison, Mary Shore, Teresa Woods et al. · Acta Obstetricia Et Gynecologica Scandinavica · 1987 · 79 citations
Nursing, Anesthesiology, Obstetrics +16