MedicineEndocrinologyPhysiologyBiosensorsDiabetologyExercise TestingBlood Glucose MonitoringContinuous Glucose MonitoringDiabetes MellitusGlucose HomeostasisGlycemic MonitoringMetabolic MonitoringAccuracyBlood Glucose Meter AccuracyGlucose Homeostasis During ExerciseGlucose MonitoringGlucose Monitoring DevicesGlucose QuantificationGlucose SensorsLaboratory Plasma Glucose Testing
BACKGROUND: Despite technological advances, the accuracy of continuous glucose monitoring (CGM) systems may not always be satisfactory with rapidly changing glucose levels, as is notable during exercise. We compare the performance of two current and widely used CGM systems, Dexcom G4 Platinum (Dexcom) and Medtronic Paradigm Veo Enlite system (Enlite), during both rest and exercise in adults with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: Paired sensor and plasma glucose (PG) values (total of 431 data pairs for Dexcom and 425 for Enlite) were collected from 17 adults (37.3 ± 13.6 years) with T1D. To evaluate and compare the accuracy of sensor readings, criteria involving sensor bias (sensor minus PG levels), absolute relative difference (ARD), and percentage of readings meeting International Organization for Standardization (ISO) criteria were considered. RESULTS: Both Dexcom and Enlite performed equally well during the rest period, with respective mean/median biases of -0.12/-0.02 mmol/L versus -0.18/-0.40 (P = 0.78, P = 0.66) mmol/L and ARDs of 13.77/13.34% versus 12.38/11.95% (P = 0.53, P = 0.70). During exercise, sensor bias means/medians were -0.40/-0.21 mmol versus -0.26/-0.24 mmol/L (P = 0.67, P = 0.62) and ARDs were 22.53/15.13% versus 20.44/14.11% (P = 0.58, P = 0.68) for Dexcom and Enlite, respectively. Both sensors demonstrated significantly lower performance during exercise; median ARD comparison at rest versus exercise for both Dexcom and Enlite showed a P = 0.02. More data pairs met the ISO criteria for Dexcom and Enlite at rest, 73.6% and 76.9% compared with exercise 48.2% and 53.9%. CONCLUSION: Dexcom and Enlite demonstrated comparable overall performances during rest and physical activity. However, a lower accuracy was observed during exercise for both sensors, necessitating a fine-tuning of their performance with physical activity.
23
Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose
William L. Clarke, Daniel J. Cox, Linda Gonder‐Frederick et al. · Diabetes Care · 1987 · 1.4K citations
Medicine, Endocrinology, Biosensors +16
Barriers to Physical Activity Among Patients With Type 1 Diabetes
Anne‐Sophie Brazeau, Rémi Rabasa‐Lhoret, Irène Strychar et al. · Diabetes Care · 2008 · 586 citations · Full text
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Diabetes Care · 2009 · 313 citations · Full text