EngineeringMeasurementMechanical EngineeringEducationConvective Heat TransferRamp-heating MethodHeat Transfer ProcessCalibrationThermal AnalysisThermal ModelingThermodynamicsInstrumentationElectrical EngineeringThermal PhysicsHeat TransferAerospace EngineeringHeat Transfer EnhancementTemperature MeasurementThermal ManagementTransient Thermal MeasurementAerodynamicsRamp HeatingThermal SensorThermal EngineeringDetailed Uncertainty Analysis
The uncertainty associated with the convective heat transfer coefficient obtained in transient thermal measurement is often high, especially in high-speed flow. The present study demonstrates that the experimental accuracy could be much improved by an actively controlled ramp heating instead of the conventional step-heating approach. A general design guideline for the proposed ramp-heating method is derived theoretically and further demonstrated by simulation cases. This paper also presents a detailed experimental study for transonic turbine blade-tip heat transfer. A repeatable, high-resolution tip heat transfer coefficient contour is obtained through transient infrared measurement with the proposed ramp-heating method. Detailed uncertainty analysis shows that the resulting heat transfer coefficient uncertainty level is much lower than the experimental data currently available in the open literature. The ramp-heating approach is especially recommended to the high-speed heat transfer experimental research community to improve the accuracy of the transient thermal measurement technique.