PubMed · 1984 · 52 citations · 0 references
MedicineVeterinary PhysiologyAnesthesiaPulmonologyVentilationAirway Clearance TechniquesHigh-frequency VentilationMechanical VentilationMucociliary ClearanceBronchial Mucociliary ClearanceChest Wall MechanicsHigh-frequency Chest Wall OscillationMucus Clearance MeasurementPressure OscillationsSpontaneous Breathing ModesSpontaneous Breathing PatternsTracheal Mucociliary Clearance
We compared the tracheal mucus clearance rate (TMCR) in anesthetized dogs during spontaneous breathing (SB), ventilation by high-frequency oscillation at the airway opening (HFO/AO), and ventilation by high-frequency oscillation of the chest wall (HFO/CW). The HFO/AO was carried out by using a piston pump with a high impedance transverse flow at the proximal end of the endotracheal tube; HFO/CW was effected by creating rapid pressure oscillations in an air-filled cuff wrapped around the lower thorax of the animal, causing small tidal volumes at the mouth. The TMCR was measured by observing the rate of displacement of a charcoal marker in the lower trachea; a fiberoptic bronchoscope was used to deposit the marker before each experiment and to relocate it after a 5-min run. In 7 dogs, mean TMCR during control (SB) was 8.9 +/- 3.5 mm/min. At 13 Hz with an oscillatory tidal volume (VTO) of 1.5 ml/kg, mean TMCR was 240% of control with HFO/CW (p less than 0.001) and 76% of control with HFO/AO (NS). During HFO/AO at 20 Hz and a VTO of 3 ml/kg, mean TMCR was 97% of control. We conclude that high-frequency ventilation by rapid chest wall compression enhances tracheal mucus clearance when compared with spontaneous breathing, whereas high-frequency oscillation at the mouth does not.