PubMed · 1982 · 15 citations · 0 references
MedicineOphthalmologySurgeryOphthalmic SurgeryCataract SurgeryEndoscopic SurgeryForeign Body RemovalForeign Body RetrievalIntraocular Foreign BodyAnterior Segment Foreign Body RemovalEndoscopic-assisted RemovalIntraocular Foreign Body InjuryIntraocular Foreign Body RemovalOcular Foreign Body RemovalSurgical EndoscopySurgical Operating Microscope Use
Pars plana endoscopy was used to guide removal of a large nonmagnetic intraocular foreign body from an eye with corneal scarring and irregularity of such a degree the view through the operating microscope was not adequate to permit such surgery.