EuroIntervention · 2016 · 110 citations · 22 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyInterventional CardiologyBalloon AngioplastyCoronary AngioplastyCoronary Artery DiseaseCoronary AtherectomyPercutaneous Coronary InterventionStent PlacementAngiographic SuccessBalloon Inflation PressureBalloon-expandable StentsCalcified Lesion AngioplastyCoronary Balloon AngioplastyCoronary StentingGainTortuosity
AIMS: Calcific coronary lesions impose a rigid obstacle to optimal balloon and stent expansion and the 20 to 30 atm limit that non-compliant (NC) balloons reach can be insufficient. The aim of our study was to evaluate the safety and efficacy of a new dedicated super high-pressure NC balloon (OPN NC®; SIS Medical AG, Winterthur, Switzerland). METHODS AND RESULTS: We retrospectively evaluated a consecutive series of 91 lesions in which conventional NC balloons at maximal pressure failed to achieve an adequate post-dilatation luminal gain and were therefore treated with an OPN NC balloon up to 40 atm. Angiographic success was defined as residual angiographic diameter stenosis <30%. MLD and %DS were measured at baseline, after NC balloon, OPN NC balloon and stent implantation. Angiographic success was achieved in 84 lesions (92.3%). All of the remaining lesions received rotational atherectomy with the exception of two cases in which rotational atherectomy was not attempted because of small vessel size and excessive tortuosity. MLD and acute gain were significantly greater and %DS was significantly lower post OPN NC balloon compared with conventional NC balloon inflation (p<0.001). No coronary perforations occurred. No acute or 30-day follow-up MACE was reported. CONCLUSIONS: When conventional NC balloons fail, the new OPN NC dedicated high-pressure balloon provides an effective and safe alternative strategy for the dilatation of resistant coronary lesions.
22
Angiographic Patterns of In-Stent Restenosis
Roxana Mehran, George Dangas, Gary S. Mintz et al. · Circulation · 1999 · 1.3K citations
Christopher P. Cannon, Alexander Battler, Ralph G. Brindis et al. · Journal of the American College of Cardiology · 2001 · 686 citations · Full text
Safety of Coronary Sirolimus-Eluting Stents in Daily Clinical Practice
Philip Urban, Anthony Gershlick, Giulio Guagliumi et al. · Circulation · 2006 · 321 citations
Medicine, Cardiology, Surgery +14
Coronary Stenting After Rotational Atherectomy in Calcified and Complex Lesions
Issam Moussa, Carlo Di Mario, Jeffrey Moses et al. · Circulation · 1997 · 315 citations · Full text
Medicine, Cardiology, Surgery +17