PubMed · 1999 · 61 citations · 0 references
Open access
MedicineCardiologySurgeryInterventional CardiologyUltrasonographyUltrasoundArterial InterventionsCoronary Artery ImagingIntravascular ImagingStent PlacementVascular ImagingVascular UltrasoundComplications Of Stent PlacementCoronary Stent AssessmentIn-stent ThrombosisStent Apposition AssessmentStent MalappositionStent Patency AssessmentVascular Stent ImagingVascular Stenting
We report a case of late stent malapposition occurring 6 months after intracoronary beta-irradiation detected by three-dimensional intravascular ultrasound, in spite of good apposition immediately after the procedure. Volumetric quantification revealed that stent volume remained unchanged, whereas total vessel volume increased by 13% after 6 months within the stent area. The increase of the vessel volume took place mainly in the proximal part of the stent, where the malapposition was located.