Publication | Closed Access
Young investigator challenge: Validation and optimization of immunohistochemistry protocols for use on cellient cell block specimens
76
Citations
17
References
2016
Year
Nearly one-half of the antibodies tested in the current study failed initial validation using IHC conditions that were established in the study laboratory for FFPE material. Although some antibodies subsequently met validation criteria after optimization of conditions, a few continued to demonstrate inadequate immunoreactivity. These findings emphasize the importance of validating IHC protocols for methanol-fixed tissue before clinical use and suggest that optimization for alcohol fixation may be needed to obtain adequate immunoreactivity on CCBs.