DentistryMechatronics EngineeringOrthodonticsMachine VisionMaxillofacial ImagingSensorsMandibular AnatomyMandibular KinematicsMandibular Range Of MotionMotion CaptureAccuracyCamerasMandibular Excursive MovementsMandibular Position RecordingPositional Measurement ErrorsRedundant ComputationRotational Jaw Movements
Photostereometry has widely been applied to the measurement of mandibular movements in 6 degrees of freedom. In order to improve the accuracy of this measurement, we developed a system utilizing small LEDs mounted on the jaws in redundant numbers and a 5000 pixel linear charge-coupled device (CCD) as a photo-sensor. A total of eight LEDs are mounted on the jaws, in two sets of four, by means of connecting facebows, each weighing approximately 55 g. The position of the LEDs are detected in three-dimensions by two sets of three CCD cameras, located bilaterally. The position and orientation of the mandible are estimated from the positions of all LEDs measured in the sense of least-squares, thereby effectively reducing the measurement errors. The static overall accuracy at all tooth and condylar points was considered to lie within 0.19 and 0.34 mm, respectively, from various accuracy verification tests.