Publication | Closed Access
Human serum and myocardium digoxin
45
Citations
0
References
1976
Year
Cardiac MuscleSerum DigoxinCardiomyopathyCardiothoracic SurgeryCardiovascular DiseasePhysiologyDiastolic FunctionLinear CorrelationCardiovascular PhysiologyCardiovascular FunctionHuman SerumMedicineCardiologyDigoxin ConcentrationsAnesthesiologyCardiac Pathology
Linear correlation was demonstrated between serum digoxin and papillary muscle digoxin concentrations in patients undergoing mitral valve surgery. The mean ratio of myocardial tissue to serum digoxin concentrations was 6711. This result supports the use of serum digoxin as a guide for assessing the degree of digitalization under steady-state conditions.