Concepedia

Publication | Open Access

A Measure of Peripheral Nerve Stimulation Efficacy Applicable to H-Reflex Studies

20

Citations

14

References

1996

Year

Abstract

Our findings indicate that for mixed nerve stimulation (e.g., tibial or ulnar nerve) the M-wave can be a reliable indicator of the centrally propagating sensory volley. Due to the high correlation between CAP and M-wave amplitude in these nerves, a small number of M-waves can give a good estimate of the size of the group I sensory volley. On the other hand, when nerves with only partially overlapping fibre diameter populations are stimulated (e.g., the soleus muscle nerve), the M-wave is not well correlated with the group I sensory volley and thus may not be used as a measure of the size of the input volley for H-reflex studies.