Publication | Closed Access
MRI of coronary arteries: 2D breath-hold vs 3D respiratory-gated acquisition.
116
Citations
0
References
1995
Year
The 2D breath-holding approach reveals a better image quality. However, the 3D respiratory-gated acquisition is less operator dependent, faster, and less strenuous for patients.