PubMed · 1989 · 26 citations · 0 references
MedicineClinical SciencesAnesthesiaGastroenterologyHemodynamic ManagementCardiovascular MonitoringGastrointestinal EndoscopyOxygen TherapyArterial Oxygen SaturationHeart RateHemodynamic Monitoring During EndoscopyLower Gastrointestinal EndoscopyOxygen SaturationOxygenation StatusPulse OximetersPulse Oximetry
Continuous monitoring of arterial oxygen saturation and heart rate with a pulse oximeter was performed in 100 consecutive patients undergoing esophagogastroduodenoscopy (78) or colonoscopy (22). Twenty-four patients had decreases in their estimated arterial PO2 level to less than 60 mm Hg during or just after the procedure. In 15 patients the hypoxemia was transient, but in nine others, treatment was required. Twenty patients also developed a tachycardia greater than 120 beats/minute.