The American Surgeon · 2006 · 16 citations · 6 references
MedicineSurgeryHistologyReconstructive SurgeryWound HealingHernia RepairHernia SurgeryDense Irregular Connective TissueFibrous Tissue ArchitectureHernia ComplicationsHernia FormationLong-term Side EffectsPathologic Gross FindingsRecurrent Hernia RepairTissue-sparing Surgery
The positioning of mesh and plug is routinely performed in hernioplasty, but knowledge about the long-term side effects of plug-induced fibrosis on the vas is incomplete. This is the first case of a documented fibrotic vas deferens obstruction resulting from compression of the plug that was in direct contact with the vas. During subsequent repair for a recurrent hernia, the cord and the plug appeared enveloped in dense fibrous tissue. Microscopy confirmed gross surgical findings. To reduce this morbidity, we suggest a cremaster sparing surgery, avoiding the positioning of bioprosthesis in direct contact with the vas deferens. We also found that positioning of a flat mesh over the transversalis fascia will avoid the unnecessary contact between mesh and bare vas below the transversalis fascia.
6
Herniorrhaphy With Polypropylene Mesh Causing Inguinal Vasal Obstruction
David Shin, Larry I. Lipshultz, Marc Goldstein et al. · Annals of Surgery · 2005 · 212 citations · Full text
R. C. Silich, C. K. McSherry · Surgical Endoscopy · 1996 · 37 citations