PubMed · 1987 · 11 citations · 0 references
Natural SciencesChemistryPharmaceutical AnalysisAnalytical ChemistryChromatographic AnalysisAnalytical ChromatographyChromatographyContrast AgentsInstrumental AnalysisLiquid ChromatographyAnalytical Liquid ChromatographyHigh-performance Liquid ChromatographyHigh-performance Liquid Chromatography Method DevelopmentIodinated Contrast Media
A simple, accurate and precise high-performance liquid chromatographic method for determination of iopentol in urine and serum is presented. The modifications of the method necessary for the determination of some other non-ionic contrast agents and in other biologic fluids are also presented.