PubMed · 1980 · 13 citations · 0 references
MedicineOphthalmologySurgeryOcular OncologyOncologic SurgeryOphthalmic SurgeryChoroidal TumorsMelanoma SurgeryOcular TumorsUveal DiseaseUveal MelanomaUveal SurgeryIntraocular Pressure ElevationIntraocular Pressure ManagementMalignant Melanoma ExcisionUveal Melanoma MetastasisUveal NeoplasiaUveal Tumor SurgeryUveal Tumors
The standard surgical technique for enucleation of an eye containing a malignant melanoma of the uvea elevates intraocular pressure markedly and may thereby disseminate tumor cells and cause death. It is possible to enucleate an eye bear a malignant melanoma of the choroid without elevating intraocular pressure to more than 27 mm/Hg by employing a manometric intraocular pressure regulating system and the adjustable cryo-ring. The value of this method of enucleation in diminishing tumor deaths remains unknown.